5 Port Solenoid Valve PK/RK Series Features:
High-flow rate, low-cost
5 Port Pilot Operated Solenoid Valve RK20 Series
Pilot Operate/ Rubber seal
Model No | Mounting | Port | Solenoid | Position | Port size |
Effective area (mm2) |
Pressure range MPa (kgf/cm2) |
RKS2420 | In-line mounting | 5 | Single | 2 | Rc1/4 | 18 |
0.15~1.0 (1.5~10) |
RKD2420 | Double |
0.1~1.0 (1.0~10) | |||||
RKD3420 | 3•Closed center | 14.4 |
0.15~1.0 (1.5~10) | ||||
RKE3420 | 3•Exhaust center | ||||||
RKO3420 | 3•Pressure center |
● Voltage/ AC110, 220V (50/60Hz), DC24V
● Wiring/Lead wire, DIN connector
Individual Wiring Type Manifold MFU☐-RK20
.
L\N | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 |
L1 | 84 | 112 | 140 | 168 | 196 | 224 | 252 | 280 | 308 | 336 | 364 | 392 | 420 | 448 | 476 | 504 | 532 | 560 | 588 |
L2 | 72 | 100 | 128 | 156 | 184 | 212 | 240 | 268 | 296 | 324 | 352 | 380 | 408 | 436 | 464 | 492 | 520 | 548 | 576 |
● Unit: mm
http://fontal-auto.com/?wpdmdl=4594
5 Port Pilot Operated Solenoid Valve RK50 Series
Pilot Operate/ Rubber seal
Model No | Mounting | Port | Solenoid | Position | Port size |
Effective area (mm2) |
Pressure range MPa (kgf/cm2) |
RKS2450 | In-line mounting | 5 | Single | 2 | Rc3/8 | 45 |
0.15~1.0 (1.5~10) |
RKD2450 | Double |
0.1~1.0 (1.0~10) | |||||
RKD3450 | 3•Closed center | 36 |
0.15~1.0 (1.5~10) | ||||
RKE3450 | 3•Exhaust center | ||||||
RKO3450 | 3•Pressure center |
● Voltage/ AC110, 220V (50/60Hz), DC24V
● Wiring/Lead wire, DIN connector
Individual Wiring Type Manifold MFU☐-RK50
.
L\N | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
L1 | 93 | 126 | 159 | 192 | 225 | 258 | 291 | 324 | 357 |
L2 | 80 | 113 | 146 | 179 | 212 | 245 | 278 | 311 | 344 |
● Unit: mm
5 Port Pilot Operated Solenoid Valve PK80 Series
Pilot Operate/ Rubber seal
Model No | Mounting | Port | Solenoid | Position | Port size |
Effective area (mm2) |
Pressure range MPa (kgf/cm2) |
PKS2480 | Sub-base mounting | 5 | Single | 2 | Rc1/2, 3/4 | 80(Rc1/2) 90(Rc3/4) |
0.15~1.0 (1.5~10) |
PKD2480 | Double |
0.1~1.0 (1.0~10) | |||||
PKD3480 | 3•Closed center | 70 |
0.15~1.0 (1.5~10) | ||||
PKE3480 | 3•Exhaust center | ||||||
PKO3480 | 3•Pressure center |
● Voltage/ AC110, 220V (50/60Hz), DC24V
● Wiring/Lead wire, DIN connector
Individual Wiring Type Manifold MF☐-PK80
.
L\N | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
L1 | 124 | 170 | 216 | 262 | 308 | 354 | 400 |
L2 | 112 | 158 | 204 | 250 | 296 | 342 | 388 |
● Unit: mm