The HiMC Magnetic Contactor series employs a modular design which allows quick and simple mounting of auxiliary contact blocks, timers, mechanical latching blocks, etc. HiMC provides convenience, economic benefit and high reliability.
|
|
|
Superior design for industrial applications such as motor control centers, the HiMC contactor is appropriate to various control systems, and favored by shipyard and power plant; where high reliability and performance are the criteria.
|
|
|
•
|
Significantly extended mechanical and electrical life through increased contact capacity |
•
|
Noise-free operation through the use of new materials and DC control method |
•
|
Free voltage in control power using electronic circuits |
•
|
New model with high performance and reliability |
|
|
HiMC 9 - HiMC 50 (Small Frame Size Contactor) |
|
•
|
The electrical and mechanical lifetime of HiMC has been significantly extended.
|
|
New metarials prevent any generation of corroded substances, and the core maintains noise-free status with the help of special anti-rush oil treatment.
|
•
|
Various accessories can be attached easily.
|
•
|
Terminal wiring is designed to meet IEC 60529 and protection degree of IP 20. |
|
By using clips, HiMC's coil can be replaced and its frequency is available in both 50Hz and 60Hz.
|
|
|
|
HiMC 65 - HiMC 800 (Large Frame Size Contactor) |
|
•
|
The electrical and mechanical lifetime of HiMC has been significantly extended. The optimized design of the arc chamber minimizes contact erosin.
|
|
HiMC contactor maintains noise-free operation through the DC-control method.
|
•
|
HiMC contactor is available in both AC/DC and 50Hz / 60Hz with an electronic circuit which enables operation through voltage drop.
|
•
|
HiMC contactors canbe used in various environments by adopting special plastic (CTI/600V) which has heat & waterproof characteristics.
|
•
|
By adopting a cassette unit, the coil assembly can be replaced conveniently.
|
|
As the cover of HiMC contactor can be easily opened, maintenance is very conevenient.
|
•
|
Two auxilliary contact blocks of 1NO+1NC can be attached to each side of HiMC, allowing auxiliary contacts to be added up to 4NO+4NC.
|
|
|
|
|
|
|
Thermal Overload Relay (HiTH Series) |
|
•
|
Current range covering all HiMC contactor rating 0.12 to 800 A, 9 frame sizes
|
|
Compensating ambient temperature -25C - 55C
|
•
|
Safety cover for main terminal & control terminal
|
•
|
Seperated mechanical part to increase safety
|
•
|
Addtional auxiliary contact 1NO+1NC (1a1b)
|
|
Three operational to indicate relay status
|
•
|
Built-in trip free mechanism to make trip at any position
|
•
|
Differential trip feature for effective motor protection, 40-60% of trip time at phase loss
|
•
|
Seperate mounting unit to mount separately with screws or DIN rail
|
|
|
|
Digital Motor Protection Relay (HiMP Series) |
|
Economic Type
|
Standard Type
|
Deluxe Type
|
1) Various Protective Function
- Over current
- Under current
- Phase failure
- Phase unbalance
- Restriction
2) Various Wiring Method
- Tunnel type
- Terminal screw type
- Dorect connection type
|
1) Various Protective Function
- Over current
- Under current
- Phase failure
- Phase unbalance
- Reverse phase
- Stall & Lock
2) Various Wiring Method
- Tunnel type
- Terminal screw type
- Dorect connection type
|
1) Various Protective Function
- Over current & Under current
- Phase failure & Phaseunbalance
- Reverse phase & Stalll & Lock
- Earth leakage r short circuit (Option)
2) Alert Function
- Overload alert
- Accumulated operating time alert
- Setting time alert
3) Display Function
- Display ampere
- Trip cause & Trip current
- Seperable display part
4) Various Wiring Method
- Terminal screw type
- Tunnel type
5) Trip Characteristic
- Selectable inverse & definite
|
|